SITRANS FM MAG 1100 F Electromagnetic Flow Meter Sensor

Brand: Siemens AG

The SITRANS FM MAG 1100 F sensor is especially designed for the food & beverage and pharmaceutical industries and is available with hygienic and flexible process connections. 

It meets all sanitary requirements and is 3A certified and EHEDG approved.

Specifications

Brand

Excitation Frequency (Mains Supply: 50 Hz/60 Hz)

  • DN 2 … 65 (1/12” … 2-1/2”): 12.5 Hz/15 Hz
  • DN 80, 100 (3”, 4”): 6.25 Hz/7.5 Hz

Process Connection Nominal Size

  • MAG 1100 (Ceramic) DN 2 … DN 100 (1/12” … 4”)
  • MAG 1100 (PFA) DN 10 … DN 100 (3/8” … 4”)

Mating Flanges

  • EN 1092-1 (DIN 2501), ANSI B 16.5 Class 150 and 300 or equivalent
  • Option: DN 2 … 10 (1/12” … 3/8”): G1/2”/NPT 1/2” pipe connection adapters

Ambient Temperature

  • Standard sensor -40 … +100° C (-40 … +212° F)
  • Ex sensor -20° to +60° C (-4 … +140° F)
  • Compact with transmitter MAG 5000/6000 -20 … +60° C (-4 … +140° F)
  • Compact with transmitter MAG 6000 I -20 … +60° C (-4 … +140° F)
  • Compact with transmitter MAG 6000 I Ex -20 … +60° C (-4 … 140° F)

Temperature of Medium

  • MAG 1100 (Ceramic) -20 … +150° C (-4 … +302° F)
  • MAG 1100 Ex (Ceramic) -20 … +150° C (-4 … +302° F)
  • MAG 1100 (PFA) -30 … +130° C (-22 … +266° F)
  • Suitable for steam sterilization at 150° C (302° F)

Temperature Shock MAG 1100 (Ceramic) - Duration ≤ 1 min, Followed By 10 Min Rest

  • DN 2, 3 (1/12”, 1/8”) No limitations
  • DN 6, 10, 15, 25: Max. ΔT ≤ 80° C/min (1/4”, 3/8”, 1/2”, 1”: Max. ΔT ≤ 144° F/min)
  • DN 40, 50, 65: Max. ΔT ≤ 70° C/min (1-1/2”, 2”, 2-1/2”: Max. ΔT ≤ 126° F/min)
  • DN 80, 100: Max. ΔT ≤ 60° C/min (3”, 4”: Max. ΔT ≤ 108° F/min)

Temperature Shock MAG 1100 (PFA)

  • Maximum ± 100° C (212° F) momentarily

Operating Pressure MAG 1100 (Ceramic)

  • DN 2 … 65: 40 bar (1/12” … 2-1/2”: 580 psi) •
  • DN 80: 37.5 bar (3”: 540 psi)
  • DN 100: 30 bar (4”: 435 psi)
  • Vacuum: 1 x 10-6 barabs (1.5 x 10-5 psiabs)

Operating Pressure MAG 1100 (PFA)

  • 20 bar (290 psi)
  • Vacuum: 0.02 barabs (0.3 psiabs)
  • DN 80 … DN 100: CO₂ pressure Max. 7 bar (101.5 psi)

Mechanical Load (Vibration)

  • 18 … 1000 Hz random in x, y, z, directions for 2 hours according to EN 60068-2-36
  • Sensor: 3.17 g rms
  • Sensor with compact MAG 5000/6000 mounted transmitter: 3.17 g rms
  • Sensor with compact MAG 6000 I/6000 I Ex mounted transmitter: 1.14 g rms
  • For compact installation with the MAG 6000 I, transmitter to be supported to avoid tension on sensor part.

Enclosure Rating (Standard)

  • IP67 to EN 60529 (NEMA 4X), 1 mH₂O for 30 min
  • EMC - 2014/30/EU

Enclosure Material

  • MAG 1100 - Stainless Steel AISI 316L/1.4404

Terminal Box Material

  • Standard - Fibre glass reinforced polyamide (Not for Ex)
  • Option - Stainless Steel AISI 316/1.4436

Fixing Studs Material

  • Stainless Steel AISI 304/1.4301
  • Number and size to EN 1092-1: 2001

Gaskets Material Standard

  • EPDM (Max. 150° C, PN 40 (Max. 302° F, 600 psi))

Gaskets Material Option

  • Graphite (Max. 200° C, PN 40 (Max. 392° F, 600 psi))
  • PTFE (Max. 130° C, PN 25 (Max. 266° F, 300 psi))
  • Stainless Steel, AISI 316 /1.4436

Pipe Connection Adapters Material DN 2, 3, 6 and 10 (1/12”, 1/8”, ¼" and 3/8”)

  • Hastelloy C-22/2.4602
  • PVDF

Liner MAG 1100 (Ceramic)

  • DN 2, 3 (1/12”, 1/8”): Zirconium oxide (ZrO₂) (ceramic)

Liner MAG 1100 (PFA)

  • DN 6 … 100 (1/4” … 4”): Aluminum oxide Al2O3
  • Reinforced PFA (Not for Ex)

Electrodes MAG 1100 (Ceramic)

  • DN 10 … 100 (3/8” … 4”): Platinum with gold/Titanium brazing alloy

Electrodes MAG 1100 (PFA)

  • DN 2 … 6 (1/12” … 1/4”): Platinum
  • DN 10 … 15 (3/8” … 1/2”): Hastelloy C-276/2.4819
  • DN 25 … 100 (1” … 4”): Hastelloy C-22/2.4602

Cable Entries

  • Remote installation 2 x M20 or 2 x 1/2” NPT
  • Compact installation - MAG 5000/MAG 6000: 4 x M20 or 4 x 1/2” NPT, MAG 6000 I: 2 x M25 (for supply/output), MAG 6000 I Ex: 2 x M25 (for supply/output)

  • Food Industry
  • Beverage Industry
  • Pharmaceutical Industry

show more