SITRANS FM MAG 3100 Electromagnetic Flow Meter Sensor
Brand: Siemens AGSITRANS FM MAG 3100 from Siemens USA is an electromagnetic flow sensor with a large variety of liners, electrode material and with grounding electrodes as standard.
Electrodes capable of withstanding the most extreme processes and various liners are also available.
The fully welded construction provides a ruggedness that fits almost every flow application.
Features- Wide Range Of Sizes: DN 15 To DN 2000 (½” To 78”)
- The Flexible Design Is For All Applications Not Covered By The Standard Industry-Specific Sensors: MAG 1100, MAG 1100 F, MAG 3100 P And MAG 5100 W
- Wide Pressure Range: PN 6 To PN 100 ANSI Class 150/300, AS 2129, AS 4087, JIS K10 And K20. On Request Up To 690 Bar (10,000 Psi)
- Wide Range Of Electrode And Liner Material To Fit Even The Most Extreme Process Media
- Fully Welded Construction Provides A Ruggedness That Suits The Toughest Applications And Environments
- Easy Commissioning, The SENSORPROM Unit Automatically Updates Settings
- Designed To Allow Patented SITRANS F M In-Situ Verification Using The SENSORPROM Fingerprints.
Specifications
Brand
Nominal Size
- MAG 3100: DN 15 ... DN 2000 (1/2” ... 78”)
- MAG 3100 HT: DN 15 … DN 300 (1/2” ... 12”)
Excitation Frequency (Mains Supply: 50 Hz/60 Hz)
- MAG 3100 - DN 80 - 150 (3” - 6”): 6.25 Hz/7.5 Hz
- MAG 3100 - DN 200 - 1200 (8” - 48”): 3.125 Hz/3.75 Hz
- MAG 3100 - DN 1400 - 2000 (54” - 78”): 1.5625 Hz/1.875 Hz
- MAG 3100 HT - DN 80 - 150 (3” - 6”): 6.25 Hz/7.5 Hz
- MAG 3100 HT - DN 200 - 300 (8” - 12”): 3.125 Hz/3.75 Hz
- MAG 3100 - DN 15 - 65 (1/2” - 2-1/2”): 12.5 Hz/15 Hz
- MAG 3100 HT - DN 15 - 65 (1/2” - 2-1/2”): 12.5 Hz/15 Hz
Flange
- EN 1092-1, Raised Face Flange
- ANSI B16.5 (~BS 1560), Raised Face Flange
- AS 2129, Raised Face Flange
- AS 4087, Raised Face Flange
- JIS B 2220:2004
Ambient Temperature
- Standard -40° to 100° C (-40° to +212° F)
- Ex Sensor: -20° to +60° C (-46° to +140° F)
MAG 3100 Compact with Transmitter
- MAG 5000/6000 -20 … +60° C (-4 … +140° F)
- MAG 6000 I -20 … +60° C (-4 … +140° F)
- MAG 6000 I Ex -20 … +60° C (-4 … +140° F)
MAG 3100 HT Compact with Transmitter
- MAG 5000/6000 -20 … +60° C (-4 … +140° F)
- MAG 6000 I -20 … +60° C (-4 … +140° F)
- MAG 6000 I Ex -20 … +60° C (-4 … +140° F)
MAG 3100 Operating Pressure
- Soft rubber 0.01 ... 100 bar (0.15 ... 1450 psi)
- EPDM 0.01 ... 40 bar (0.15 ... 580 psi)
- Linatex 0.01 ... 40 bar (0.15 ... 580 psi)
- Ebonite 0.01 ... 100 bar (0.15 ... 1450 psi)
- PTFE - DN ≤ 300 (≤ 12”): 0.3 ... 50 bar (4 ... 725 psi) - 350 ≤ DN ≤ 600 (14” ≤ DN ≤ 24”): 0.3 ... 40 bar (4 ... 580 psi)
- PFA - DN 15 ... 150 (1/2” … 6”): Vacuum 0.02 ... 50 bar (0.29 ... 725 psi)
MAG 3100 HT Operating Pressure
- PTFE Teflon - DN 15 ... 300 (1/2” … 12”): 0.3/0.6 ... 50 bar (4/8 ... 725 psi) (180° C (356° F)) Factory mounted grounding rings type E in stainless steel and stainless steel terminal box. Can only be used with remote transmitter.
- PFA - DN 15 ... 150 (1/2” … 6”): Vacuum 0.02 ... 50 bar (0.29 ... 725 psi)
Enclosure Rating
- IP67 to EN 60529/NEMA 4X/6, 1 mH₂O for 30 min
- Option: IP68 to EN 60529/NEMA 6P, 10 mH₂O cont.
Pressure Drop at 3 m/s
- As straight pipe
Test Pressure
- 1.5 x PN (where applicable)
Mechanical Load (Vibration)
- 18 ... 1000 Hz random in x, y, z, directions for 2 hours according to EN 60068-2-36
- Sensor: 3.17 g rms
- Sensor with compact MAG 5000/6000 mounted transmitter: 3.17 g rms
- Sensor with compact MAG 6000 I/ 6000 I Ex mounted transmitter: 1.14 g rms
MAG 3100 Temperature of Medium
- Soft rubber 0 … +70° C (32 … 158° F)
- EPDM -10° to +70° C (14 … 158° F)
- Linatex (rubber) -40° to +70° C (-40° to +158° F) (for temperatures below -20° C (-4° F) AISI 304 or 316 flanges must be used)
- Ebonite 0° … 95° C (32 … 203° F)
- PTFE -20 … +100° C (-4 … +212° F)
- PFA -20 … +100° C (-4 … +212° F)
MAG 3100 HT Temperature of Medium
- 18 to 1000 Hz random in x, y, z, directions for 2 hours according to EN 60068-2-36
- Sensor: 3.17 g rms
- Sensor with compact MAG 5000/6000 mounted transmitter: 3.17 g rms
- Sensor with compact MAG 6000 I/ 6000 I Ex mounted transmitter: 1.14 g rms
- PTFE -20 … +150° C (-4 … +302° F)
- PTFE -20 … +180° C (-4° to +356° F) Factory mounted grounding rings type E in stainless steel and stainless steel terminal box. Can only be used with remote transmitter
- PFA -20 … +150° C (-4 … +300° F)
EMC
- 2014/30/EU
Flange and Housing Material
- Carbon steel ASTM A 105, with corrosion resistant coating
- Corrosivity category C4, according to ISO 12944-2 or stainless steel AISI 304/1.4301 flanges and carbon steel housing, with corrosion resistant coating
- Corrosivity category C4, according to ISO 12944-2 or stainless steel AISI 316L/1.4404 flanges and housing, polished
Electrode Material
- Stainless Steel AISI 316Ti/1.4571
- Hastelloy C-276/2.4819 (PFA: Hastelloy C-22/2.4602)
- Platinum/Iridium
- Titanium
- Tantalum
Grounding Electrode Material
- PTFE: no grounding electrodes
- PFA: optional in Hastelloy, Tantalum or Platinum
- MAG 3100: Soft rubber, EPDM, Linatex, Ebonite: available with grounding electrodes in stainless steel AISI 316Ti/1.4571 or Hastelloy
MAG 3100 Terminal Box (Remote Version Only)
- Standard fibre glass reinforced polyamide
- Option Stainless Steel AISI 316/1.4436
- Ex Stainless Steel AISI 316/1.4436
MAG 3100 HT Terminal Box Remote Version Only)
- Standard fibre glass reinforced polyamide (Max. 150° C (302° F))
- Stainless Steel AISI 316/1.4436
- Ex Stainless Steel AISI 316/1.4436
MAG 3100 Cable Entries
- Remote installation 2 x M20 or 2 x 1/2” NPT
- Compact installation - MAG 5000/MAG 6000: 4 x M20 or 4 x 1/2” NPT - MAG 6000 I: 2 x M25 or 2 x 1/2” NPT (for supply/output) - MAG 6000 I Ex: 2 x M25 or 2 x 1/2” NPT (for supply/output)
MAG 3100 HT Cable Entries
- Remote installation 2 x M20 or 2 x 1/2” NPT
Standard Production Calibration
- Zero-Point, 2 x 25 % and 2 x 90 %
MAG 3100 Special Calibration
- 5-Point calibration: 20 %, 40 %, 60 %, 80 %, 100 % of factory Qmax
- 10-Point calibration: ascending and descending at 20 %, 40 %, 60 %, 80 %, 100 % of factory Qmax
- Matched-pair calibration: default, 5-point or 10-point
Ex Sensor in Compact or Remote Version with MAG 6000 I Ex
- ATEX, FM, CSA, IECEx, EAC Ex, NEPSI - Zone 1 Ex d e ia IIC T6 Gb - Zone 1 Ex e ia IIC T6 Gb
- ATEX, FM, CSA, IECEx - Zone 21 Ex tD A21 IP67
- FM - XP IS Class I, Div. 1 Groups A, B, C, D - DIP Class II+III, Div. 1 Groups E, F, G
Standard Sensor With/Without MAG 5000/6000/6000 I
- FM - NI Class I, Div. 2 Groups A, B, C, D - NI Class I Zone 2 Groups IIC
MAG 3100 Drinking Water
- WRAS (WRc, BS690 cold water, GB)
- NSF/ANSI Standard 61 (Cold water, US)
- ACS listed (F)
- DVGW W270 (D)
- Belgaqua (B)
- MCERTS (GB) (EPDM or PTFE lining with AISI 316 or Hastelloy electrodes)
Pressure Equipment
- PED conforming: All EN 1092-1 flanges - 2014/68/EU
- CRN
Others
- EAC (Russia, Belarus, Kazakhstan)
- KCC (South Korea)
- CMC/CPA (China)
- Process Industry
- Chemical Industry
- Steel Industry
- Mining
- Utility
- Power Generation And Distribution
- Oil And Gas / HPI
- Water And Waste Water