SITRANS LR250 HEA Radar Level Transmitter - Hygienic Encapsulated Antenna
Brand: Siemens AGThe SITRANS LR250 Hygienic Encapsulated Antenna is a 2-wire 25 GHz pulse radar level transmitter with sanitary and hygienic approvals for continuous monitoring of liquids, slurries, and pastes within the food, beverage, chemical, and pharmaceutical industries to a range of 20 m (66 ft) (antenna dependent).
Features- Fully encapsulated horn antenna design with FDA approved and USP Class VI compliant, TFM 1600 PTFE lens
- < 0.8 μ Ra surface finish for maximum cleanability and hygiene requirements commonly required in sanitary environments
- Chemically resistant TFM 1600 PTFE lens is also suitable for aggressive or corrosive materials
- Approved device in accordance with 3-A, EHEDG EL Class I and/or EHEDG EL Aseptic Class I
- Cost effective replacement for transmitters made of exotic materials
- Graphical local user interface (LUI) makes operation simple with plug-and-play set-up using the intuitive Quick Start Wizard
- Industry standard process connections including ISO 2852, DIN 11851, DIN 11864-1, DIN 11864-2, DIN 11864-3, and Tuchenhagen Varivent Type F and N
- LUI displays echo profiles for diagnostic support
- 25 GHz high frequency and 2 inch (50 mm) process connection/antenna allow for easy mounting
- Insensitive to mounting location and obstructions, and less sensitive to nozzle interference
- Communication using HART, PROFIBUS PA, or FOUNDATION Fieldbus
- Process Intelligence signal processing for improved measurement reliability and Auto False-Echo Suppression of fixed obstructions
- Programming using infrared Intrinsically Safe handheld programmer or over a network using SIMATIC PDM, Emerson AMS, or Field Device Tools, such as PACTware or Fieldcare via SITRANS DTM.
- Functional Safety (SIL 2). Device suitable for use in accordance with IEC 61508 and IEC 61511
Specifications
Brand
Certifications & Approvals
- CSA
- FM
- ATEX
- IECEx
- INMETRO
- NEPSI
- CE
- RCM
- FCC
- EAC
- Lloyd's Register of Shipping
- RED
- EHEDG
Wetted Material
- TFM, PTFE
Process Temperature
- -40° to 170° C (-40° to 338° F)
Ambient/Storage Temperature
- -40° to 80° C (-40° to 176° F)
Measuring Range
- 50 mm to 20 m (2 in to 66 ft)
Process Connection
- 2”, 3” & 4” Sanitary Clamp According to ISO 2852
- DN 50, DN 80 & DN 100 Aseptic/Hygienic Threaded to DIN 11864-1 [Form A]
- DN 50, DN 80 & DN 100 Aseptic/Hygienic Flanged to DIN 11864-2 [Form A]
- DN 50, DN 80 & DN 100 Aseptic/Hygienic Clamp According to DIN 11864-3 [Form A]
- DN 50, DN 80 & DN 100 Hygienic Union According to DIN 11851
- Type F (50 mm) & Type N (68 mm) Tuchenhagen Varivent
Communication
- HART, PROFIBUS PA, or FOUNDATION Fieldbus
Enclosure/Body Material
- Enclosure: Aluminum, Polyester Powder-Coated
Materials of Construction
- Antenna: 316L Stainless Steel (1.4435 or 1.4404) and TFM 1600 PTFE Lens
Cable Inlet
- 2 x M20 x 1.5
- 2 x 1/2” NPT
Power Supply
- Nominal 24 Vdc (Max. 30 Vdc)
Environmental Protection
- Type 4X / NEMA 4X
- Type 6 / NEMA 6
- IP68
- IP67
- Food & Beverage
- Chemical
- Pharmaceutical