PTD-1 Local Readout Display

Brand: Tel-Tru Manufacturing Co.

The PTD-1 loop-powered display is designed for direct readout in milli-Amps VC, percent of full scale, or engineering units.

The display is configurable from -1999 to +1999, and may be used on most instruments with 4-20 mA output and a DIN 43650 electrical connection.

Specifications

Accuracy

  • ≤ ± 0.05 % of Full Scale Output (BFSL, RSS)

Applications

  • Harsh Environments
  • High Vibration

Compensated Temperature

  • -18° to 77° C (0° to 170° F)

Display

  • -1,999 to 1,999
  • LCD Display
  • LED Display

Electrical Connectors

  • DIN 43650

Electrical Protection

  • Short Circuit Protected: up to 40 Vdc

Enclosure, Body Material

  • High-Impact ABS Plastic

Environmental Protection

  • IP66
  • NEMA 4X

Gasket Material

  • Neoprene

Insulation Resistance

  • 1,000 megaohms at 50 VDc

Mounting

  • Surface

NACE & NIST

  • NIST Traceable Calibration Certificate

Operating Temperature

  • -18° to 93° C (0° to 200° F)

Output

  • 4-20 mA

Repeatability

  • ≤ ± 0.05 % of Full Scale Output

Reverse Polarity Protection

  • Yes

RFI/EMI Protection

  • Internal Filtering

Stability

  • Long Term Stability: ≤ ± 0.05 % of Full Scale Output Per Year

Storage Temperature

  • -29° to 93° C (-20° to 200° F)

Supply Voltage

  • Excitation: 12-36 Vdc

Temperature Effect

  • ≤ ± 0.5 % of Full Scale Output over Compensated Range [Combined Effects of Zero & Full Scale Output with Reference at 21° C (70° F)]

Update Time

  • < 100 milliseconds

Voltage Drop

  • 2.5 Vdc, Max.

Zero Balance

  • ≤ ± 1 % of Full Scale Output

show more