2200, 3300/8300, 3500/8500, 3600/8600, 3800/8800

Brand: Westlock

Intellis is a family of fully-integrated control monitors that provide cost-effective valve automation and intelligent networking via the major network protocols.
Features
  • Dedicated network modules (PACs) for all major protocols
  • Simple in-field conversion of network protocols
  • Multiple housing options (resin, aluminum, stainless steel)
  • Models approved for all hazardous area applications
  • Control and monitoring for rotary and linear valves
  • Non-contact position monitoring by Hall effect sensors
  • Integrated pneumatic actuation control via pre-wired Falcon II solenoid valves
  • On-line predictive and maintenance-related diagnostics
  • Eliminates wiring cost of conventionally hardwired I/O systems
  • Reduces design engineering man-hours
  • Range of drive shaft options
  • Visual indication Beacon available in a choice of styles and colors

Specifications

Brand

Applications

  • Engineering Design
  • Integration
  • Start-Up Support
  • Training
  • Turnkey Installations

Approvals & Certifications

  • ATEX
  • IEC Ex
  • NAMUR VDI/VDE 3845

BSP Connection

  • 1/4” BSP

Bushing Material

  • Aluminum Enclosure: Oil Impregnated Bronze
  • Stainless Steel Enclosure: Nylon

Coil Voltage

  • Solenoid: 24-240 Vac/dc

Communication

  • AS-Interface Version 3.0 - 2200, 3500/8500, 3800/8800 Series
  • DeviceNet - 2200, 3500 / 8500, 3800 / 8800 Series
  • FOUNDATION Fieldbus - 2200, 3300 / 8300, 3600 / 8600 Series
  • PROFIBUS DP - 2200, 3500/8500, 3800/8800 Series
  • Transmission Speed - Baud Rate: 125, 250, 500 Kbps - DEVICENET 2200, 3500/8500, 3800/8800 Series
  • Transmission Speed - Baud Rate: 167 Kbps - AS-Interface Version 3.0 2200, 3500/8500, 3800/8800 Series
  • Transmission Speed - Baud Rate: 31.25 Kbps - FOUNDATION FIELDBUS 2200, 3300/8300, 3600/8600 Series
  • Transmission Speed - Baud Rate: 9.6 to 12,000 Kbps - PROFIBUS 2200, 3500/8500, 3800/8800 Series

Consumption

  • Current Consumption Per Network Monitor: (2 In/2 Out) 11 mA (Power) - 59 mA (1 In/1 Out) - AS-Interface Version 3.0 2200, 3500/8500, 3800/8800 Series
  • Current Consumption Per Network Monitor: 120 mA - PROFIBUS 2200, 3500/8500, 3800/8800 Series
  • Current Consumption Per Network Monitor: 18-24 mA IS - FOUNDATION FIELDBUS 2200, 3300/8300, 3600/8600 Series
  • Current Consumption Per Network Monitor: 45 mA + 20-25 mA / Coil - DEVICENET 2200, 3500 / 8500, 3800 / 8800 Series

Distance

  • 1,600 feet (485 metres) Trunk + 512 feet (155 metres) Drop, Max.
  • 3,960 feet (1,200 metres) Trunk, Max.
  • 300 feet (90.9 metres) with Repeater, Max.
  • 6,720 feet (1,900 metres) Including Spurs, Max.
  • 900 feet (273 metres) with Repeater, Max.

Electrical Connectors

  • Junction Box

Enclosure Finish

  • Aluminum with Powder Coat Finish
  • Stainless Steel with Electro-Polished Finish

Enclosure, Body Material

  • 316 Stainless Steel
  • Aluminum
  • Engineered Resin
  • Stainless Steel

Environmental Protection

  • Explosion-proof - 2200 Series
  • Intrinsically Safe - 3300/8300, 3600/8600 Series
  • IP66
  • Non-Hazardous - 3500 / 8500, 3800 / 8800 Series

Flow Rate

  • 1.1 Cv

Materials of Construction

  • Beacon Visual Indicator: Co-Polyester
  • Hardware: Stainless Steel

NPT Connection

  • 1/4” NPT

Shaft Material

  • Stainless Steel

Solenoid Type

  • 3/2-Way
  • 5/2-Way
show more