LM1 Anti-Clogging Submersible Transmitter
Brand: Winters Instruments
Specifications
- Heavy-duty submersible transmitter for level measurement in sludge and slurry installations
- 316L SS housing with anti-clogging sensor and reinforced diaphragm seal
- Standard ranges from psi: 2 to 50 (kPa: 13.79 to 344.7, bar: 0.1379 to 3.447), optional ranges from up to psi: 140 (kPa: 965.3, bar: 9.653)
- ±0.25% accuracy
- 33 feet (10 meters) of vented cable standard, other lengths also available
- NEMA 6P / IP68 for full immersion
Displaying prices & availability for Ohio, United States in CAD. Change location.
Models matching criteria: 7
- Pressure Range - psi: 0 to 2 (Inches WC: 0 to 55)
100+ In Stock
$831.00
CAD
Does not ship to OH, United States
- Pressure Range - psi: 0 to 15 (Inches WC: 0 to 415)
50+ In Stock
$463.00
CAD
Does not ship to OH, United States
- Pressure Range - psi: 0 to 50 (Inches WC: 0 to 1,384)
50+ In Stock
$2,221.00
CAD
Does not ship to OH, United States
- Pressure Range - psi: 0 to 5 (Inches WC: 0 to 138)
50+ In Stock
$1,672.00
CAD
Does not ship to OH, United States
- Pressure Range - psi: 0 to 10 (Inches WC: 0 to 277)
50+ In Stock
$427.00
CAD
Does not ship to OH, United States
- Pressure Range - psi: 0 to 25 (Inches WC: 0 to 692)
50+ In Stock
$1,037.00
CAD
Does not ship to OH, United States
- Pressure Range - psi: 0 to 30 (Inches WC: 0 to 830)
3 In Stock
$2,346.00
CAD
Does not ship to OH, United States
Specifications
Brand
Accuracy
- ± 0.25 % of Full Scale Output
- ± 0.5 % of Full Scale Output
Approvals & Certifications
- EMC (Electromagnetic Compatibility): EN 50081-1/2
- RoHS
Burst Pressure
- psi: 6 to 150 (kPa: 41.37 to 1,034, bar: 0.413 to 10.34)
Cable Length
- 33 feet (10 metres) of Vented Cable
Cable Material
- Polyurethane
- Teflon
Circuit Protection
- Reverse Polarity Protection
Diaphragm Material
- 316L Stainless Steel w/ 1Cr18Ni9Ti
Electrical Connectors
- 1/2” NPT Male Submersible Conduit
Electrical Protection
- Lightning Protection
Enclosure, Body Material
- 316L Stainless Steel with Anti-Clogging Sensor
Environmental Protection
- IP67
- IP68
- NEMA 6P
Mounting
- Pressure Port: Flush Mounted
Operating Temperature
- -40° to 85° C (-40° to 185° F)
Output
- 2-Wire: 4-20 mA/Vs = 10-36 Vdc
- 3-Wire: 0-10 V/Vs = 10-36 Vdc
- 3-Wire: 0-5 V/Vs = 10-36 Vdc
Overpressure & Static Pressure Limits
- Overpressure psi: 3 to 75 (kPa: 20.68 to 517.1, bar: 0.206 to 5.171)
Pressure Range
- bar: 0 to 3.447
- Inches WC: 0 to 1,384
- kPa: 0 to 344.7
- psi: 0 to 50
Response Time
- < 10 milliseconds
- Manufactured for Level Measurement in Sludge & Slurry Installations Including Lifting Stations